8644 WAGO I/O
System 750
16,5mm width/station Solenoid Valves 6526 and 6527
The solenoid valve Types 6526 and 6527 consist of
a pneumatic valve body fi tted with Type 6106 rocker
pilot valve. The principle allows switching of high
pressures together with low power consumption and
fast response times. The pilot valves are equipped
with manual override as a standard.
Specifi cation
Body material
PA (Polyamide)
seal materials
NBR
Medium
lubricated and non lubricated dry compressed air;
neutral gases (10 μm fi lter)
Port connections
Flange for MP12
Pneumatic module
Type MP12 with G 1/8,
Push-in Ø 8 mm
NPT 1/8
Manual override
Standard
Operating voltage
24 V DC
Nominal power
2 W, 1W
Duty cycle
Continuous operation 100%
Electr. connection on
valve
Tag connector acc. to DIN EN 175301-803
(previously DIN 43650) Form C
Mounting
with 2 screws M3 x 30
Installation
As required, preferably with actuator upright
Flow rate: QNn value air
[l/min]:
Measured as overpressure to the atmospheric pressure
1 bar pressure difference
Pressure values [bar]
Measured as overpressure to the atmospheric pressure
Response times [ms]
Measured according to ISO 12238
1)
Version with auxiliary pilot air
2)
Electric connection with manual override.
3)
Closing time approx. 5 ms higher when used together with valve unit
Control
function
Orifi ce [mm]
QNn value air
[l/min]
Pressure range
[bar]
Nominal power
[W]
Response times
Voltage/
Frequency
[V/Hz]
Item no.
Opening
[ms]
Closing
[ms]
3)
C
3/2-way valve, pilot-controlled,
currentless, Port 2 decreased
6 700 1,0 - 10
1)
2 20 12 24 V DC 156 842
1,0 - 10
1)
2 20 12 24 V DC 163 028
2)
2,0 - 10 2 20 12 24 V DC 156 318
2,0 - 10 2 20 12 24 V DC 158 944
2)
2,0 - 8,0 1 20 17 24 V DC 156 840
2,0 - 8,0 1 20 12 24 V DC 158 947
2)
D
3/2-way valve, pilot-controlled,
currentless, Port 2 pressurized
6 700 1,0 - 10
1)
2 20 12 24 V DC 163 029
2)
2,0 - 10 2 12 20 24 V DC 156 320
2,0 - 10 2 20 12 24 V DC 158 946
2)
2,0 - 8,0 1 17 20 24 V DC 156 841
H
5/2-way valve, pilot-controlled,
currentless, Port 1 connected to
port 2, port 4 exhausted
6 700 1,0 - 10
1)
2 20 12 24 V DC 156 828
1,0 - 10
1)
2 20 12 24 V DC 163 030
2)
2,0 - 10 2 20 12 24 V DC 156 337
2,0 - 10 2 20 12 24 V DC 158 942
2)
2,0 - 8,0 1 20 17 24 V DC 156 827
2,0 - 8,0 1 20 12 24 V DC 158 943
2)
 




Ordering chart for valves